Model: IC-275 Bulletin: B1005 Subject: Improve the stability of the center meter 1. Replace C81 on the main board (currently 120pf 50 CH type capacitor) with a 120 pf 50V SH temperature coefficient capacitor (ICOM P/N 918-05960).