SB-820 TR-7625 Final Module Relpacement 3-20-80 When replacing the output hybrid with a "Red" Mitsubishi logo, and additional 47pF cap must be installed between teh M57712H output terminal and the RFO wrap post. Install the M57712H with white silicone heatsink compound. Install a 47pF as shown between the hybird output and the RFO terminal. Spread L21 as necessary for at least 30W output at approximately 5.5 A total current consumption. Note: Hybirds not having a red mitsubishi logo do not require the additional cap or adjustment. JEB/yn (c) 32080TKC